Problems with marble cladding can include bowing expansion loss of strength cracking and even detachment from the building.
Marble facade failure.
What climates cause stone facade failure.
The marble façade on hotel t erraza in ljungby sweden clad with a swedish dolomitic marble is now facing a renovation of about 1 5 million us due to deterioration 共 bowing and cracking 兲.
Testing has shown that stoneply does not suffer the problem of thermal hysteresis.
In europe there are building facades with bowed marble slabs from both the cooler climates of finland and denmark to the warmer climates of portugal and spain.
Marble for your building or if you have.
Derives from the transformation of.
Façade failure due to thermal hysteresis the failure of the amoco building in chicago serves as arguably the most infamous example of thermal hysteresis.
A building clad in marble panels atten tion to fabrication detailing and signs of distress can make the difference between a minor repair project and complete wall system failure.
Suffering a similar fate the chase lincoln first bank of rochester new york had to strip its 27 story headquarters of its carrara marble skin in a job that took three years to complete.
In the usa buildings in several states have had problems.
Marble is a metamorphic rock that.
The problem with marble facades is not limited to one climate or one type of marble.
Nyc buildings glossary facade conditions for educational purposes only 1.
Here we will address the cause of and solution to hysteresis and marble facade failure.
Distressed marble panel investigation and granite reclad design after routine inspection of the building s facade revealed cracking and bowing of the marble panels amoco sought an expert to investigate the nature and extent of the damage and to develop solutions to restore the facade s structural and aesthetic integrity.
Material properties and history.
Intent scope and purpose this glossary is intended to be used only as an educational tool by those interested in visual inspections of facade conditions.
The glossary does not include any guide as to the impact of the various listed conditions on the public.
Clad with nearly 6 000 tons of carrara marble imported from italy the facade lasted less than 15 years before requiring replacement.
Constructed as the headquarters for standard oil of indiana in 1974 the building changed names along with the company in 1985 to become.